INPUT DATA
Frequency (Input) | 50 Hz |
---|---|
Mains supply types | TT / TN / IT |
Grid connection | CEE32 plug red 5-pin / 30 cm including neutral conductor |
Optional adapter set | CEE16 red, CEE blue camping plug, safety plug 16A |
Nominal voltage | 230 V (1-phase) / 400 V (3-phase) |
Nominal current (configurable) | 6-32 A 1-phase or 3-phase |
Power consumption for standby | 1.9 W (LED not lit), 4.2 W (LED brightly lit) |
Charging socket | Type 2 infrastructure socket with mechanical lock |
Residual current device | 30 mA AC, 6 mA DC |
Supply line cable cross-section | 6 mm**2 |
Maximum charging power | 22 kW |
GENERAL DATA
Width
|
146 mm |
---|---|
Height
|
251 mm |
Depth
|
96 mm |
Weight | 1,86 kg |
Weight incl. packaging | 3,22 kg |
Protection class | IP 54 (IP 44 with type 2 cable plugged in) |
Installation | Indoors or outdoors |
Ambient temperature range | -25 °C to +40 °C (without direct sunlight) |
Humidity | 5% - 95% |
Max. altitude | 2000 m |
Impact resistance | IK08 |
PV optimisation | Dynamic PV surplus charging from 1.38-22 kW (automatic 1-/3-phase switching) |
Network connection | WLAN* |
Type of installation | Hanging upright |
Average ambient temperature over 24 hours | Max. 35° C |